Banner Q4XTBLAF300-Q8 - 1.2 Laser Safety

Default Icon
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(SELECT)(TEACH)
Press to select menu items in Setup mode
Press and hold for longer than 2 seconds to start
the currently selected TEACH mode (the default is
two-point TEACH)
(+)(DISP)
Press to navigate the sensor menu in Setup mode
Press to change setting values; press and hold to
increase numeric values
Press and hold for longer than 2 seconds to switch
between light operate (LO) and dark operate (DO)
(-)(MODE)
Press to navigate the sensor menu in Setup mode
Press to change setting values; press and hold to
decrease numeric values
Press and hold for longer than 2 seconds to enter
Setup mode
NOTE: When navigating the menu, the
menu items loop.
1.4 Laser Description and Safety Information
CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may
result in hazardous radiation exposure. Do not attempt to disassemble this sensor for repair. A defective unit
must be returned to the manufacturer.
Class 1 Lasers
Class 1 lasers are lasers that are safe under reasonably foreseeable conditions of operation, including the use of optical
instruments for intrabeam viewing.
Laser wavelength: 655 nm Output: < 0.20 mW Pulse Duration:
7 µs to 2 ms
Q4X Stainless Steel Laser Sensor
www.bannerengineering.com - Tel: 763.544.3164 5