Method Action Result
Push Button Press and hold TEACH
for longer than 2 seconds.
Light Operate
and flash alternately
on the display. The BGS indicator
flashes.
Dark Operate
and flash alternately
on the display. The BGS indicator
flashes.
Remote Input No action required. N/A
3. Teach the sensor.
Method Action Result
Push Button Press TEACH to teach the target.
The new switch point flashes rapidly
and the sensor returns to Run mode.
Remote Input Single-pulse the remote input.
T
Table 5: Expected TEACH Behavior for One-Point Background Suppression
See Figure 20 on page
28
for the minimum object separation.
Condition TEACH Result Display
One valid TEACH point Sets a switch point in front of the taught
distance by the vertical minimum object
separation.
The switch point distance flashes
on the display.
One invalid TEACH point
Sets a switch point at the following location:
Model Switch Point
100 mm threaded barrel models 75
300 mm threaded barrel models 200
110 mm flush mount models 85
310 mm flush mount models 210
and the switch point
distance flash alternately on the
display.
3.6.5 Dual (Intensity + Distance)
Dual (intensity + distance) TEACH records the distance and amount of light received from the reference surface. The
output switches when an object passing between the sensor and the reference surface changes the perceived distance or
amount of returned light. For more information on dual TEACH mode, see Dual (Intensity + Distance) Mode on page
30
.
NOTE: To use the following instructions, set the sensor to = . The DYN, FGS, and BGS indicators
are amber.
NOTE: To program the sensor using remote input, remote input must be enabled ( = ).