Delay at Power Up
< 750 ms
Maximum Torque
Side mounting: 1 N·m (9 in·lbs)
Nose mounting: 20 N·m (177 in·lbs)
Ambient Light Immunity
> 5,000 lux
Connector
Threaded Barrel Models:
Integral 5-pin M12/Euro-style male quick
disconnect (QD)
Flush Mount Models: Integral 4-pin M12/Euro-style male quick
disconnect (QD)
Construction
Housing: 316 L stainless steel
Lens cover: PMMA acrylic
Lightpipe and display window: polysulfone
Temperature Effect
0.05 mm/°C at <125 mm (threaded barrel models)/< 135 mm
(flush mount models)
0.35 mm/°C at 300 mm (threaded barrel models)/< 310 mm (flush
mount models)
Chemical Compatibility
Compatible with commonly used acidic or caustic cleaning and
disinfecting chemicals used in equipment cleaning and sanitation.
ECOLAB
®
certified.
Compatible with typical cutting fluids and lubricating fluids used in
machining centers
Application Note
For optimum performance, allow 10 minutes for the sensor to warm
up
Environmental Rating
IEC IP67 per IEC60529
IEC IP68 per IEC60529
IEC IP69K per DIN40050-9
Vibration
MIL-STD-202G, Method 201A (10 Hz to 60 Hz, 0.06 inch (1.52 mm)
double amplitude, 2 hours each along X, Y and Z axes), with sensor
operating
Shock
MIL-STD-202G, Method 213B, Condition I (100G 6x along X, Y and Z axes,
18 total shocks), with sensor operating
Operating Conditions
10 °C to +50 °C (+14 °F to +122 °F)
35% to 95% relative humidity
Storage Temperature
–25 °C to +75 °C (13 °F to +167 °F)
Required Overcurrent Protection
WARNING: Electrical connections must be made by
qualified personnel in accordance with local and
national electrical codes and regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current
Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to http://www.bannerengineering.com.
Supply Wiring (AWG) Required Overcurrent Protection (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
Certifications
Industrial
Control
Equipment
3TJJ
Class 2 power
UL Environmental Rating: Type 1
chemical compatibility certified
ECOLAB is a registered trademark of Ecolab USA Inc. All rights
reserved.
Q4X Stainless Steel Laser Sensor
26 www.bannerengineering.com - Tel: 763.544.3164

Table of Contents

Related product manuals