Operating manual for BAUER RAINSTAR Series TX Plus  36 
 
MACHINE DATA 
 
Machi
ne.Dat
. 
Anm. Facto
ry 
settin
gs 
 
Min. 
value 
Max.  
value 
              Description 
   0    600  0  1000  Pipe length                                        [m] 
   1    125  40  200  Pipe diameter                                     [mm] 
   2    1850  500  3000  Reel diameter                             [mm] 
   3    11,27  5,00  30,00  Windings per layer 
   4    240  50  1000  Big chain wheel 
   5    9  5  40  Small chain wheel  
   6    4  1  20  Number of magnets 
   7    0,89  0,70  1,00  Pipe ovality 
   8    3  0  45  First impulse to the switch-off motor                 [Sec.] 
   9    160  0  300  Short impulses to the shut-off motor                 [msec] 
   10    3  1  5  Time between short impulses [Sec.] 
   11    100  0  250  Number of short impulses 
   12    0 
1 
0  1  Shut –off system   
0 = only regulating motor turbine ( without shut-off valve)   
1 = both regulating motors  ( with shut-off valve ) 
   13    8,2 
4,1 
1  25  Impulses to close the regulating valve  [Sec] 
TX60 , TX100 - 8,2 sec. 
TX20 , TVR 20 , TVR 60, F 30, F 40 - 4,1 sec. 
   14    0 
1 
0 2  Pressure switch 
0 = Pressure switch not in function 
1 = Pressure switch in function 
2 = Pressure switch only for start 
   15    0  0  160.0  62,5 Distance of the impulses with roll Ø 80 at the PE-pipe   [ mm ]  
0 = works with formula ( Machine. Dat. 0 to 7 ) 
   16    1  0  1  Length sensor  
0 = Round sensor for roll 
1 = Double sensor 
   17    0 
1 
0  1  Open shut-off valve                            
0 = shut off valve opens with one impulse ( 12 sec. ) –low pressure  
1 = shut-off valve opens with the same impulses as it closes -
overpressure 
   18    0 
1 
0 1  Pressure switch 
0 = shut-off valve open when pressure is too low offen (low pressure ) 
1 = shut-off valve closes if pressure is too low (overpressure)  
   19    8  0  200  Time delay shut-off gear to shut-off valve [Sec]. 
   20    0 
1 
0 1  Speed monitoring 
0 = Monitoring off 
1 = Monitoring on 
   21    0 
1 
0 1  Unit view 
0 = metric units [m] 
1 = US –unit [ft.] 
    30    0  0  1  0 = GSM-Modem not active 
1 = GSM-Modem 
2 = GSM-Modem, only numbers on the SMS-list 
    31    -  -  -  First telephone number to call „A“ 
    31    -  -  -  Second telephone number to call „B“