Operating manual for BAUER RAINSTAR series TX Plus 61
19.4 SETTING 1
st
GEAR SHUT-OFF
Fix the shut-off lever (11) in the shut-off position (60 - 62 mm).
Switch into 1
st
gear (position “I“).
Screw down the setscrew (12) to the gear shift lever (7) and turn it in until the shut-off point (see above) is
reached! Lock the setscrew (12).
19.5 SETTING 2
nd
GEAR SHUT-OFF
The shut-off lever (11) remains fixed in the shut-off position (60 - 62 mm). Switch into 2
nd
gear (position “II”).
Screw down the setscrew (13) with the cap nut to the shut-off lever (7) and turn it in until the shut-off point is
reached (see above). Lock the setscrew (13).
13
11
12
60 - 62
11
13
60 - 62