EasyManua.ls Logo

Bauer Rainstar TX Plus Series - Testing the Shut-Off; 23 Service and Maintenance

Bauer Rainstar TX Plus Series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating manual for BAUER RAINSTAR Series TX Plus 78
22.6 TESTING THE SHUT-OFF
Put the shut-off frame (13) on the PE-pipe (last layer).
Move the shut-off lever (9) to “PE-pipe retraction” position.
Pull the shut-off frame (13) into the shut-off position ( =
X mm
from the reel).
The shut-off lever must jump into the shut-off position.
23 SERVICE AND MAINTENANCE
We cannot emphasise often enough that proper service is essential for the operating reliability and service life
of a machine. At the end of every irrigation season the RAINSTAR should be thoroughly checked and cleaned,
and all parts re-greased carefully.
Machine part Service interval Lubricant, grease, oil
1. Helically grooved spindle of
the winding mechanism
every 250 hours Alvania Grease 3
2. Drive chain of winding
mechanism
every 250 hours Alvania Grease 3
3. Driver (spindle nut) of
winding mechanism
every 250 hours,
change recommended
after 2500 service hours
Alvania Grease 3
4. Driving chain as required Alvania Grease 3
5. Change-speed gearbox
Change oil for first time after 500
service hours and then every
500 to 800 hours or at least once
a year
6,0 l oil SAE 90 EP
6. Ball race every 500 hours through grease nipple
Alvania Grease 3
7. Jack
as required Oil SAE 20,Alvania Grease3
through grease nipple
8. Shut-off point on the cart lift
bracket (see page 32,point 7)
as required Alvania Grease 3
9. Screwed joints Tightening torques
Turntable side frame 210 Nm
Ball race on turntable and
undercarriage
85 Nm
Trailer coupling 210 Nm

Table of Contents