Operating manual for BAUER RAINSTAR Series TX Plus 40
7 OPTION - SMS
The ECOSTAR 4300 can be operated with an external MC52i-GSM-Modem by Cinterion.
By sending an SMS the RAINSTAR can be started or stopped and the status can be requested.
Commands
Start Starts the machine.
Stop Stops the machine.
Speed ### set the speed between 3 and 400 m/h., e.g.:
speed 24
Status Shows the current status of the machine.
SMS can be typed in both upper- or lower case or mix .
If you call the modem from a GSM-telephone you will receive an SMS with the Status.
If the machine is operated by keyboard (display is lighted) the SMS-function is deactivated in order to
prevent multiple sms and to block remote operating. When receiving an SMS User active is sent retun.
Status
SPEED 30.0m/h
DOSE 22 mm
TIME 14:10 STOP18:16
STATUS OPERATION
DISTANCE 123m
BATTERY 12.8V
CHARGE ON 0.231A
SMS, sent by PR10-12, contains information about
irrigation.
The following messages are sent by SMS:
PRESSURE LOW: Start pump, to get pressure on the machine.
STOP SENSOR: The machine can be moved to a new field
STOP REMOTE: The machine was stopped by an SMS,
STOP DISTANCE: The machine has reached stop point (constant 8)
MONITORING TIME: The machine has not moved for nn minutes (Constant 4) due to a
malfunction. Check the machine before continuing.