EasyManua.ls Logo

Bauer Rainstar TX Plus Series - SMS Remote Operation

Bauer Rainstar TX Plus Series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating manual for BAUER RAINSTAR Series TX Plus 40
7 OPTION - SMS
The ECOSTAR 4300 can be operated with an external MC52i-GSM-Modem by Cinterion.
By sending an SMS the RAINSTAR can be started or stopped and the status can be requested.
Commands
Start Starts the machine.
Stop Stops the machine.
Speed ### set the speed between 3 and 400 m/h., e.g.:
speed 24
Status Shows the current status of the machine.
SMS can be typed in both upper- or lower case or mix .
If you call the modem from a GSM-telephone you will receive an SMS with the Status.
If the machine is operated by keyboard (display is lighted) the SMS-function is deactivated in order to
prevent multiple sms and to block remote operating. When receiving an SMS User active is sent retun.
Status
SPEED 30.0m/h
DOSE 22 mm
TIME 14:10 STOP18:16
STATUS OPERATION
DISTANCE 123m
BATTERY 12.8V
CHARGE ON 0.231A
SMS, sent by PR10-12, contains information about
irrigation.
The following messages are sent by SMS:
PRESSURE LOW: Start pump, to get pressure on the machine.
STOP SENSOR: The machine can be moved to a new field
STOP REMOTE: The machine was stopped by an SMS,
STOP DISTANCE: The machine has reached stop point (constant 8)
MONITORING TIME: The machine has not moved for nn minutes (Constant 4) due to a
malfunction. Check the machine before continuing.

Table of Contents

Related product manuals