EasyManua.ls Logo

Baur Sys compact 2000 M pro - Maintenance Schedule; Checking the Ignition Voltage of the Spark Gap

Baur Sys compact 2000 M pro
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance and care Syscompact 2000 M pro
80
/ 98 822-175-2
15.2 Maintenance schedule
Interval Task
After each use Check and clean the connection cables and the connection
accessories.
Further information: Chapter Checking and cleaning the connection
cables and accessories (on page 83)
Monthly Check the condition of all connection cables.
Further information: Chapter Checking and cleaning the connection
cables and accessories (on page 83)
Every 12 months
(with frequent use, every 6 months
or as required)
Check the discharging resistance of the discharge unit.
Further information: Chapter Testing the discharge unit (on page 82)
Every 12 months
(with frequent use, every 6 months
or as required)
Check the ignition voltage of the spark gap.
Further information: Chapter Checking the ignition voltage of the spark
gap (on page 80)
As required depending on the
conditions of use
Clean the system components.
Further information: Chapter Cleaning system components (on page
84)
As required Replace the IRG 2000 rechargeable batteries.
Further information: Chapter Replacing the rechargeable batteries of
the IRG 2000 (on page 85)
15.3 Checking the ignition voltage of the spark gap
Check the ignition voltage of the spark gap every 12 months or as required. The ignition
voltage must be between 500 and 1000 volts.
Procedure