1401 Warnings and safety instructions
3.3
3.5 Safety instructions – diesel engine driven pump unit
Never run the engine in an enclosed space.
Provide a proper gas-tight discharge for exhaust gases.
Provide sufficient ventilation.
Never fill the fuel tank while the engine is running.
Wear hearing protection while in the vicinity of a running engine.
DANGER
Exhaust gases contain carbon monoxide.
Carbon monoxide is a colourless, odourless and deadly gas which, when inhaled,
prevents the body from absorbing oxygen, resulting in asphyxiation. Severe carbon
monoxide poisoning can result in brain damage or death.
3.6 Safety instructions – during maintenance and repair
Work may only be performed on the pump or pump unit when the pump or pump unit has been put out
of operation.
Follow the procedure described in this manual to put the pump or pump installation out of operation.
Make sure all pressure within the pump or pump unit has been relieved before beginning the work.
When opening the pump follow all the instructions for handling the pumped liquid, such as those
concerning protective clothing, safety goggles, no smoking, etc.
Consult the Material Safety Data Sheet (MSDS) for the pumped liquid.
If the pump or pump unit is being used to pump a hazardous liquid, it must first be cleaned and
neutralised.
Protect the drive motor against unintended and unauthorised activation throughout the duration of the
work activities.
Maintenance work on the electrical system may only commence after the power supply has been
disconnected and may only be performed by personnel who have been trained and authorised to do so.
In the interest of safety, only use parts purchased from or approved by the supplier.
Modifications to the pump or pump installation or the application are only permitted after consultation
with the suppliers. The reliability of the pump or pump unit can only be guaranteed when the pump is
used for the application and in the manner for which it is intended, as specified at the time of delivery.