9.10
9.9 Shipping the pump or pump unit
If the pump must be sent to the supplier for major maintenance, repair or overhaul, the following
conditions must be met:
– The pump must be drained and thoroughly cleaned inside.
– All compartments of the drip tray under the pump and motor/engine must be drained prior to
transport.
WARNING
Leakage of environmentally harmful liquids can be extremely damaging to the
environment. Do everything necessary to prevent this.
– For compliance with the safety and environmental regulations, the shipment must be accompanied
by a ‘Declaration of no objection’.
Note
BA series pumps may be equipped with a back-pull out system. This makes it possible to remove the
bearing block with intermediate housing, mechanical shaft seal, shaft and impeller from the pump
housing as a whole without the need to remove the suction and pressure pipes.
9.10 Draining the pump
WARNING
Take the necessary precautionary measures in the case of hot, volatile, flammable
and hazardous liquids.
WARNING
Leakage of environmentally harmful liquids can be extremely damaging to the
environment. Do everything necessary to prevent this.
Note
For liquids that congeal at temperatures lower than the operating temperature, close off the suction and
pressure pipes and drain the pump and the vacuum pump as soon as the pump has been stopped.