BA series pumps
1401 Receiving, transport and storage
4.7
4.10 Removal of preservation agent
Mineral-based lubrication oil is used as the preservation agent.
Drain the preservation agent before putting the machine in operation.
If the preservation agent is detrimental to the pumped liquid, flush the pump thoroughly.
1. Drain the preservation agent. Capture the liquid. See chapter 10.
2. Flush the pump thoroughly. Capture the liquid.
3. Fit the cleaning cover and the drain plugs.
4. Dispose of the preservation agent and flushing liquid in a responsible manner.
Note
If preservation agent is to be applied again, do not reuse the old preservation agent.