BA series pumps
Receiving, transport and storage 1401
4.6
4.7 Storage longer than 6-12 months
For storage longer than 6-12 months, take the following measures:
1. Apply a layer of preservation agent to all unpainted parts and rotating parts.
2. Seal the suction flange liquid-tight.
3. Seal the connection for flushing, circulation or cooling (if present).
Note
The type of preservation agent to be used depends on the materials and the application.
Consult BBA Pumps for the correct preservation agent.
4. Fill the pump with preservation agent.
5. Slowly rotate the driveshaft one revolution by hand.
6. Seal the pressure flange liquid-tight.
WARNING
The pump units may be stacked for storage purposes. Do not stack pump units
more than two high.
4.8 Inspection during storage
1. Make sure the pump units are not stacked more than two high (if applicable).
2. Check the level of the preservation agent once every three months. Top off the preservation agent
if necessary.
3. Slowly rotate the driveshaft one revolution by hand.
4.9 Transport of pump with preservation agent
Prior to transport, check the pump for leakage of preservation agent.
WARNING
Leakage of preservation agent can cause the floor to become dangerously slippery
and may lead to preservation agent entering the environment.