BA series pumps
1401 Pump unit with diesel drive
8.1
8 Pump unit with diesel drive
8.1 Safety instructions
– Never run the engine in an enclosed space.
– Provide a proper gas-tight discharge for exhaust gases.
– Provide sufficient ventilation.
– Never fill the fuel tank while the engine is running.
– Wear hearing protection while in the vicinity of a running engine.
WARNING
It is the employer's responsibility to ensure that the safety measures (such as
protection against overload) and the resulting actions (such as shut-down of the
engine) are included in the safety circuit.
DANGER
Exhaust gases contain carbon monoxide. Carbon monoxide is a colourless,
odourless and deadly gas which, when inhaled, prevents the body from absorbing
oxygen, resulting in asphyxiation. Severe carbon monoxide poisoning can result in
brain damage or death.
8.2 Connection – general
For pump units driven by a combustion engine, the engine manual can be provided upon request.
Contact the supplier of your pump unit immediately if this manual is not present.
– The following instructions supersede any conflicting information found in the combustion engine
manual:
– Observe all applicable local safety instructions.
– Shield the engine exhaust pipe to prevent accidental contact.
– The starting system must automatically disengage when the engine is started.
– The minimum and maximum engine speed set by BBA Pumps may not be changed.
– Before starting, check the following:
• engine coolant level, if applicable
• coolant leakage, if applicable
• engine oil level
• fuel level
• fuel lines, for leakage