BA series pumps
Pump unit installation 1401
5.7
Lay the pipe so as to prevent the formation of air pockets.
Use the least possible number of bends.
Bends must have the largest possible radius.
The pipe system must be completely airtight.
In the case of a non-self-priming pump, in which the liquid does not flow towards the pump, install a
foot valve with a sufficiently large flow capacity.
In the case of polluted liquids, always install a suction strainer or solids separation screen with a
sufficiently large net opening area. The filtration particle size of the suction strainer must be equal to
or less than the solids handling specification of the pump.