BA series pumps
1401 Pump unit with diesel drive
8.37
Group 3 Specifications (Aviation Fuels)
This group of fuel specification must be used only with the appropriate fuel additive. This fuel WILL
reduce engine life and performance.
"NATO F34 (MIL-DTL-83133E)"
"NATO F35 (MIL-DTL-83133E)"
"NATO JP8 (MIL-DTL-83133E)"
"NATO F-44 (MIL-DTL-5624U)"
"NATO JP5 (MIL-DTL-5624U)"
"Jet A (ASTM D1655)"
"Jet A1 (ASTM D1655)"
NOTICE
All the above fuels can ONLY be used if the sulfur level meets the specifications that are listed in tables
C and D. An analysis of a sample of fuel must be conducted in order to check the sulfur level.
NOTICE
These fuels are only acceptable provided that these fuels are used with an appropriate fuel additive.
These fuels must meet the requirements that are stated in tables B, C and D. Fuel samples should be
analyzed for the compliance. These fuels MUST NOT exceed lubricity wear scar diameter of 0.46 mm
(0.0181 inch). The fuel lubricity test must be performed on a HFRR, operated at 60 °C (140 °F). Refer
to “ISO 12156-1 ”. Fuels must have minimum viscosity of 1.4 centistokes that is delivered to the fuel
injection pump. Fuel cooling may be required in order to maintain minimum viscosity of 1.4 centistokes
that is delivered to the fuel injection pump.
Perkins Specification for Distillate Diesel Fuel
(1)
Property UNITS Requirements “ASTM”Test "ISO"Test
Aromatics %Volume 35% maximum D1319 "ISO" 3837
Ash %Weight 0.02% maximum D482 "ISO" 6245
Carbon Residue on
10% Bottoms
%Weight 0.35% maximum D524 "ISO" 4262
Cetane Number
(2)
- 40 minimum D613/D6890 "ISO" 5165
Cloud Point °C The cloud point must not exceed
the lowest expected ambient
temperature.
D2500 "ISO" 3015
Copper Strip Corrosion - No. maximum 3 D130 "ISO" 2160
Density at 15 °C
(59 °F)
(3)
Kg / M 3 801 minimum and 876 maximum No equivalent
test
"ISO 3675",
"ISO 12185"
Distillation °C 10% at 282 °C (539.6 °F) maximum
90% at 360 °C (680 °F) maximum
D86 "ISO" 3405
Flash Point °C legal limit D93 "ISO" 2719