GB Sound speed controller SFR-1
58 BEIER-Electronic 06.02.2019
Hardness of handbrake
If the function handbrake is activated with DIP switch 4 the hardness of braking can
be set here.
The handbrake can be active only while parking/standing. Without this option, the
handbrake hits as soon as the throttle is in neutral position and the vehicle is still
rolling.
Throttle curve 1 and 2
Using the curve, the proportion between throttle signal and driving behaviour can be
set in the diagram. Both driving directions (backwards and forwards) have 10 values
(at 10 %, 20 %, 30 %, 40 %, 50 %, 60 %, 70 %, 80 %, 90 % and 100 % of throttle
signal) to adjust the driving behaviour.
For example a very sensitive acceleration behaviour for driving slowly or a limitted
maxium speed can be set.
With „reset“ the curve returns to its initial values.
The throttle curve 2 can be activated with a function while driving. This enables for
example to use throttle curve 1 for normal driving and throttle curve 2 for maneuvring
with very sensitive acceleration behaviour.
Example for nomal driving: Example for maneuvring: