X2 series with embedded CODESYS control Recommendations and limitations
SUEN00392E 2022-03
13 (61)
Normal.dotm
, 2020-09-09
Version compatibility chart X2 extreme/BoX2 extreme SC
Image
Device
description
file
CODESYS
Engineering
*1
CODESYS
runtime
package
Compiler
COM
adapter
Ethernet
adapter
Canbus
adapter
EtherCAT
Master
Modbus
RTU
Master *2
Modbus
TCP Client
*3
CANopen
Manager
1.2.1 b287
3.5.13.30
V3.5 SP13
Patch3
3.5.13.30_3
3.5.13.30
3.5.11.20
3.5.13.0
3.5.12.0
3.5.11.10
3.5.13.10
(Modbus
RTU Slave
device
3.5.10.30 *4)
3.5.13.0
(Modbus
TCP Slave
device
3.5.12.0
*4)
3.5.10.0
2.0 b367
3.5.13.30.1
V3.5 SP13
Patch3
3.5.13.30_7
3.5.13.30
3.5.11.20
3.5.13.0
3.5.12.0
3.5.11.10
3.5.13.10
(Modbus
RTU Slave
device
3.5.10.30 *4)
3.5.13.0
(Modbus
TCP Slave
device
3.5.12.0
*4)
3.5.10.0
2.0 b368*5
(Hotfix)
3.5.13.30.1
V3.5 SP13
Patch3
3.5.13.30_7
3.5.13.30
3.5.11.20
3.5.13.0
3.5.12.0
3.5.11.10
3.5.13.10
(Modbus
RTU Slave
device
3.5.10.30 *4)
3.5.13.0
(Modbus
TCP Slave
device
3.5.12.0
*4)
3.5.10.0
*1 Use stated version or newer with the version settings as described in the chart.
*2 Modbus RTU slave is not available.
*3 Modbus Server is not available.
*4 Version of configured slave (located under the Master in the project tree)
*5 Hotfix version due to iX download issue.
Persistent function (X2 control/extreme, BoX2 pro SC/BoX2
extreme SC)
The PLC functionality have support for storing non-volatile variables.
Those variabels can be stored dynamically in two different modes:
Power-fail mode (Default setting):
If the voltage drops below a hardware given threshold (that is, during a power loss or power dip),
the system instantly copies all persistent data defined in the PLC application from RAM into the
battery backed SRAM. They are verified and restored when the device is restarted.
Cyclic mode:
the PLC is instructed to store all retain and persistent data directly into SRAM synchronously
with every PLC cycle. This means all device types can use the whole available memory, which is
128 kiB. However, writing to the SRAM might increase the configured PLC cycle depending on
the size of used retain and persistent data, because a SRAM is naturally slower then a RAM.
This possible increase is dependent of the application and to find out about the possible increase
one would need to monitor the configured task(s) of the project.

Table of Contents

Other manuals for Beijer Electronics X2 control

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beijer Electronics X2 control and is the answer not in the manual?

Beijer Electronics X2 control Specifications

General IconGeneral
BrandBeijer Electronics
ModelX2 control
CategoryController
LanguageEnglish

Related product manuals