TX-1xx Series Printer Operation Manual
~ 125 ~
11.6 Data Matching
In modes other than the Direct mode, if the scale outputs multiple weighing data
at the same time, but only wants to print one or part of the data, you can use this
parameter to match the specified weighing data. For example, the scale outputs
the following:
+ 100.00 kg N
+ 50.00 kg T
+ 150.00 kg G
If you want to process only the data containing "N" identifier, you can set this
parameter to "N", as shown below:
Since the identifier "N" is behind the unit, it violates the first rule of weighing
data identification in Section "11.5 Data Filtering", the printer will not accept