1 695 301 979 2011-07-16| Beissbarth GmbH
Operating instructions | MS 75 | 25MS 75 | 25 | 25 en
4.3 Electrical connection
1. Check the correspondence of the mains tension and
the tension shown on the identification tag.
2. Ask a qualified electrician to mount a connection
plug for single-phase or (depending on the tension
you have ordered ) three-phase current (see the
electrical connections diagram inside the electrical
panel).
i The costs of arranging a mains protection device for
the plug are borne by the customer.
3. Protect the MS 75 according to specific national
rules.
4.4 Check rotation direction
Warning - malfunctioning danger!
MS 75 turns in counter-clockwise direction.
¶ Turn off the main switch.Check the manual
section dedicated to functioning anomalies
to find the cause (see chap. 5.3)
For a correct functioning of MS 75 it is extremely im-
portant that after having connected and started the ma-
chine the rotation direction corresponds to that shown
by the arrow on the control unit motor.
652022-02_Mi
Fig. 2: Check rotation direction.
5. Operating instructions
Warning - tire or rim damage danger!
Excessive pressure can e. g. result in cracks
(on the inside/outside) of the tire. The rim
can be scratched or deformed.
¶ Read the Wdk publications available in
German and English! (www.wdk.de: moun-
ting/demounting instructions – criteria
catalogue)
¶ Inner temperature of the tire must be at
least 15 °C (only in case of RFT/UHP).
¶ Read the Wdk publications available
in German and English! (www.wdk.de:
mounting/demounting instructions – tire
overheating)
¶ Adjust pressure to the type of tire.
¶ Use the plastic protections on the types of
rim that need it.
! Before demounting or mounting operations it is ext-
remely important to collect all the rim and tire data.
In this way it will be possible to know in advance the
mounting, the pressure and the required accesso-
ries!