Local air-conditioner / User Manual
any danger. In doubt, one person should
guard the outlet. Take specal care that
draned refrgerant wll not float back nto
the buldng.
Evacuate the refrgerant crcut.
Purge the refrgerant crcut wth ntrogen
for 5mn.
Evacuate agan.
Remove parts to be replaced by cuttng,
not by flame.
Purge the braze pont wth ntrogen durng
the brazng procedure.
Carry out a leak test before chargng wth
refrgerant.
Reassemble sealed enclosures accurately.
If seals are worn, replace them.
Check safety equpment before puttng
nto servce.
d) Decommssonng
If the safety s affected when the
equpment s putted out of servce, the
refrgerant charge shall be removed before
decommssonng.
Ensure suffcent ventlaton at the
equpment locaton.
Be aware that malfuncton of the
equpment may be caused by refrgerant
loss and a refrgerant leak s possble.
Dscharge capactors n a way that won’t
cause any spark.
Remove the refrgerant. If the recovery s
not requred by natonal regulatons, dran
the refrgerant to the outsde. Take care
that the draned refrgerant wll not cause
any danger. In doubt, one person should
guard the outlet. Take specal care that
draned refrgerant wll not float back nto
the buldng.
Evacuate the refrgerant crcut.
Purge the refrgerant crcut wth ntrogen
for 5mn.
Evacuate agan.
Fll wth ntrogen up to atmospherc
pressure.
Put a label on the equpment that the
refrgerant s removed.
e) Dsposal
Ensure suffcent ventlaton at the workng
place.
Remove the refrgerant. If the recovery s
not requred by natonal regulatons, dran
the refrgerant to the outsde. Take care
that the draned refrgerant wll not cause
any danger. In doubt, one person should
guard the outlet. Take specal care that
draned refrgerant wll not float back nto
the buldng.
Evacuate the refrgerant crcut.
Purge the refrgerant crcut wth ntrogen
for 5mn.
Evacuate agan.
Cut out the compressor and dran the ol.
Transportaton, markng and storage for
unts that employ flammable refrgerants
Transport of equpment contanng
flammable refrgerants
Attenton s drawn to the fact that addtonal
transportaton regulatons may exst wth respect
2. Instructons for reparng applances contanng
R290