BHT-206L4-MM-1 TC APPROVED
4-00-00
Page 12 Rev. 23 25 JUN 2019
Export Classification C, ECCN EAR99
Figure 4-1. Tailboom Upper Left Attachment Fitting (206-032-409-001)
— Recurring 110-Hour Inspection
206LS_MM_04_0001+_c01
INSPECTION PROCEDURE:
1. Inspect upper left attachment fitting for cracks, mechanical damage, corrosion damage,
loose rivets, and general condition.
2. Refer to ASB 206L-09-158 for wear, damage, and repair limits.
3. Repair fitting in accordance with ASB 206L-09-158.
4. Replace cracked or damaged fitting or loose rivets in accordance with ASB 206L-09-158.
5. If a crack is found, contact Product Support Engineering .