BHT-206L4-MM-1
5-00-00
Page 10 Rev. 24 18 JUL 2019
Export Classification C, ECCN EAR99
5-15. CHANGING INSPECTION PROGRAM
You must use either the airframe periodic inspection
program or the airframe progressive inspection
program from the start. You can change between the
two programs at any airframe operating time as
follows:
To change from a 100-hour airframe
progressive inspection program to a 100-hour
airframe periodic inspection program, do a
complete 100-hour airframe periodic
inspection.
To change from a 100-hour airframe periodic
inspection program to a 100-hour airframe
progressive inspection program, do a
complete 100-hour airframe periodic
inspection.
To change from a 300-hour airframe
progressive inspection program to a 300-hour
airframe periodic inspection program, do a
complete 300-hour airframe periodic
inspection.
To change from a 300-hour airframe periodic
inspection program to a 300-hour airframe
progressive inspection program, do a
complete 300-hour airframe periodic
inspection.