BHT-429-MPI
Table1.ScheduledInspections-10-YearInspection(continued)
INITIAL
DATAREFERENCE/IMRR
TASKNUMBER
TASKDESCRIPTIONACCESSZONES
MECHOTHER
429-MM,Chapter96
263001
6.Doafunctionalcheckofthereextinguisher
electricalsystem.
400B410
FUELSYSTEM
BHT-429-CMM-V,Chapter28
281006
1.Doanoperationalcheckoftherollovervalve.
200F,
600A
412,610
FUSELAGE
429-799-049
252103
1.Doarestoration(overhaul)ofthesingleordual
patientrestraintshoulderharnessandlapend
assemblies,ifpatientrestraintkit(429-799-049)is
installed.
N/A
ZONALINSPECTIONS
100-05
1.Doageneralvisualinspectionoftheinternal
areasofthenosecaporradomeandbatteryaccess
door(ifinstalled).
100A112
COMPLETIONTASKS
429-MM,Chapter53
1.Installpanels100A,200F ,400Band600A.
429-A-05-40-00-15A-281A-AApplicableto:ALL
Page2Issue1-10JAN2019
ECCNEAR99