Deleted.
GENERAL
1.Reviewhelicopterlogbookandensureall
recordeddiscrepancieshavebeencorrected.
2.Ensurecompliancewithallapplicable
airworthinessdirectives.
429-A-04-00-00-00A-009A-A
3.Ensurelifelimitedpartsdonotexceedservice
life.
429-MM,Chapter12
4.Ensureallrequiredlubricationtaskshavebeen
performed.
429-A-05-40-00-22A-281A-A
5.Ensureallrequiredmiscellaneousinspections
havebeenperformed,asapplicable.
429-MM,Chapter99
6.Ensureallrequiredinspectionsofinstalled
BHTkitsnotcoveredinthisinspectionhavebeen
performed,asapplicable.
7.Recordaccomplishmentofthisinspectioninthe
helicopterlogbook.
PREPARATIONTASKS
None
POWERPLANT
NOTE
Tobeperformedevery6000hoursofoper-
atingtimeorfollowing15cleaningtaskson
theinletbarrierlterassemblies,whichever
comesrst.
BHT-429-CMM-V,Chapter71
716102
1.Replacetheupperandlowerlterassembliesof
eachinletbarrierlter,ifinstalled.
N/A
710
COMPLETIONTASKS
None
Applicableto:ALL429-A-05-40-00-17A-281A-A
ECCNEAR99