BHT-429-MPI
ScheduledInspections-15,000-Houror15-YearInspection
Table1.ScheduledInspections-15,000-Houror15-YearInspection
INITIAL
DATAREFERENCE/IMRR
TASKNUMBER
TASKDESCRIPTIONACCESSZONES
MECHOTHER
DATE:__________________W.O.
FACILITY:
HELICOPTERS/N:
REGISTRYNO.:
TOTALTIME:
SIGNATURE:
NOTE
Tobeperformedevery15000hoursofoper-
atingtimeor15years,whicheveroccursrst.
GENERAL
429-A-05-40-00-01A-281A-A1.Doacomplete100-houror12-monthinspection.
429-A-05-40-00-02A-281A-A2.Doacomplete200-houror12-monthinspection.
429-A-05-40-00-04A-281A-A3.Doacomplete600-houror12-monthinspection.
429-A-05-40-00-16A-281A-A4.Doacomplete5000-hourinspection.
429-A-05-40-00-08A-281A-A5.Doacomplete12-monthinspection.
429-A-05-40-00-10A-281A-A6.Doacomplete3-yearinspection.
429-A-05-40-00-12A-281A-A7.Doacomplete5-yearinspection.
8.Reviewhelicopterlogbookandensureall
recordeddiscrepancieshavebeencorrected.
9.Ensurecompliancewithallapplicable
airworthinessdirectives.
429-A-04-00-00-00A-009A-A
10.Ensurelifelimitedpartsdonotexceedservice
life.
429-MM,Chapter12
11.Ensureallrequiredlubricationtaskshavebeen
performed.
429-A-05-40-00-22A-281A-A
12.Ensureallrequiredmiscellaneousinspections
havebeenperformed,asapplicable.
429-MM,Chapter99
13.Ensureallrequiredinspectionsofinstalled
BHTkitsnotcoveredinthisinspectionhavebeen
performed,asapplicable.
14.Recordaccomplishmentofthisinspectionin
thehelicopterlogbook.
PREPARATIONTASKS
429-MM,Chapter53
1.Removepanel600FL.
FIREPROTECTION
429-MM,Chapter26
261002
1.DiscardtheNo.1andNo.2engineredetection
sensors.
600FL710
COMPLETIONTASKS
429-MM,Chapter53
1.Installpanel600FL.
Applicableto:ALL429-A-05-40-00-20A-281A-A
ECCNEAR99
10JAN2019-Issue1Page1