BHT-429-MPI
ScheduledInspections-800-HourInspection
Procedure
Table1.ScheduledInspections-800-HourInspection
INITIAL
DATAREFERENCE/IMRR
TASKNUMBER
TASKDESCRIPTIONACCESSZONES
MECHOTHER
DATE:__________________W.O.
FACILITY:
HELICOPTERS/N:
REGISTRYNO.:
TOTALTIME:
SIGNATURE:
NOTE
Tobeperformedevery800hoursofoperat-
ingtime.
GENERAL
429-A-04-00-00-00A-009A-A
1.Ensurelifelimitedpartsdonotexceedservice
life.
429-MM,Chapter12
2.Ensureallrequiredlubricationtaskshavebeen
performed.
429-A-05-40-00-22A-281A-A3.Ensureallrequiredmiscellaneousinspections
havebeenperformed,asapplicable.
429-MM,Chapter994.Ensureallrequiredinspectionsofinstalled
BHTkitsnotcoveredinthisinspectionhavebeen
performed,asapplicable.
5.Recordaccomplishmentofthisinspectioninthe
helicopterlogbook.
PREPARATIONTASKS
429-MM,Chapter53
1.Removepanels100EL,100ER,200AL,200AR,
200DL,200DR,500A,500B,500F ,500G,600EL,
600ER,600FL,600FR,700BL,700BR,700CL,
700CR,700DL,700DR,700EL,700ER,700GL,
700GR,700H,700HL,and700HR.
DOORSANDWINDOWS
429-MM,Chapter52
253001
1.Doadetailedinspectionofthechinbubbles
(ApplicableonlyifDitchingKit(429-706-048)is
installed).
100EL,
100ER
110
MAINROTOR
429-MM,Chapter62
621001
1.Doadetailedinspectionofthemainrotorblade
assemblies.
N/A
611
429-MM,Chapter62
622001
2.Doadetailedinspectionofthemastnutlocks.N/A
611
429-MM,Chapter62
622007
3.Doadetailedinspectionofthedownstop
assemblies.
N/A
611
429-MM,Chapter62
622009
4.Doadetailedinspectionoftheplateassembly.N/A
611
Applicableto:ALL429-A-05-40-00-31A-281A-A
ECCNEAR993DEC2019-Issue1Page1