EasyManua.ls Logo

Bell 429 - Scheduled Inspections - 8000-Hour Inspection; Table 1. Scheduled Inspections - 8000-Hour Inspection

Bell 429
192 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BHT-429-MPI
ScheduledInspections-8000-HourInspection
Table1.ScheduledInspections-8000-HourInspection
INITIAL
DATAREFERENCE/IMRR
TASKNUMBER
TASKDESCRIPTIONACCESSZONES
MECHOTHER
DATE:__________________W.O.
FACILITY:
HELICOPTERS/N:
REGISTRYNO.:
TOTALTIME:
SIGNATURE:
NOTE
Tobeperformedevery8000hoursofoperat-
ingtime.
GENERAL
1.Reviewhelicopterlogbookandensureall
recordeddiscrepancieshavebeencorrected.
2.Ensurecompliancewithallapplicable
airworthinessdirectives.
429-A-04-00-00-00A-009A-A
3.Ensurelifelimitedpartsdonotexceedservice
life.
429-MM,Chapter12
4.Ensureallrequiredlubricationtaskshavebeen
performed.
429-A-05-40-00-22A-281A-A
5.Ensureallrequiredmiscellaneousinspections
havebeenperformed,asapplicable.
429-MM,Chapter99
6.Ensureallrequiredinspectionsofinstalled
BHTkitsnotcoveredinthisinspectionhavebeen
performed,asapplicable.
7.Recordaccomplishmentofthisinspectioninthe
helicopterlogbook.
PREPARATIONTASKS
1.Removepanels100DL,200AL,200AR,200F ,
and400B.
DCPOWERSYSTEM
429-MM,Chapter96
246003
1.Doanoperationalcheckofthenon-essentialbus
feederdiodes(2430CR2and2430CR3).
200AL,
200AR,
200F
216
429-MM,Chapter96
246002
2.Doanoperationalcheckoftheemergencybus
feederdiodes(2450CR1and2450CR2).
200AL,
200AR,
200F
111
429-MM,Chapter96
246005
3.Discardthebusinterconnectdisablerelay
(2430K7).
100DL111
429-MM,Chapter96
243001
4.DoafunctionalcheckofGRCUs(2430VR1and
2430VR2).
400B410
COMPLETIONTASKS
1.Installpanels100DL,200AL,200AR,200F,and
400B.
Applicableto:ALL429-A-05-40-00-18A-281A-A
ECCNEAR99
10JAN2019-Issue1Page1