EasyManua.ls Logo

Bematech BR200BT - MSI;Plessy Parameter Settings

Bematech BR200BT
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Handy Wireless Scanner
54
USER MANUAL
Start Of Configuration
MSI/Plessy Parameter Setting
Barcode
Value
Barcode Label
Description
RC14
MSI enable
RD14
MSI disable
DC70
MSI data redundant check= off
DC71
MSI data redundant check=1
DC72
MSI data redundant check=2
DC73
MSI data redundant check=3
MS01
MSI/Plessy maximum length setting
MS02
MSI/Plessy minimum length setting
SET
Confirm to save this setting (required for reading full
ASCII table and length setting)
MS03
MSI/Plessy double check digit calculate but not
transmit
MS04
MSI/Plessy double check digit without calculate and
transmit
MS05
MSI/Plessy double check digit calculate but only first
digit transmit
MS06
MSI/Plessy double check digit calculate and both
transmit
MS07
MSI/Plessy single check digit calculate but without
transmit
MS08
MSI/Plessy single check digit calculate and transmit
End Of Configuration

Table of Contents