PL-12000DP Series Parking Lift 47 P/N 5900285 — Rev. A1 — February 2023
NOTICE Your Lift arrives with a Power Unit sourced from one of a few vendors that meet or
exceed our strict requirements. Therefore, the Power Unit that came with your Lift may
differ in appearance from the drawings in this manual.
To install the Power Unit:
1. Remove the Power Unit, Vibration Dampener, and supplied hardware from packaging.
2. Line up the holes on the Mounting Plate and Vibration Dampener with the four holes in the
Mounting Bracket.
Both the Vibration Dampener and the Mounting Bracket have four holes, one in each corner. Make
sure to use all four holes to hold the Power Unit.
3. Secure the Power Unit and Vibration Dampener to the Mounting Plate using supplied hardware.
Filling the Hydraulic Fluid Reservoir
The Hydraulic Fluid Reservoir requires approximately 3.6 gallons / 13.5 liters of Hydraulic Fluid.
The Power Unit will
not
work correctly until it is filled with the approved Hydraulic Fluid.
Approved fluids are any general purpose ISO-32, ISO-46, or ISO-68 Hydraulic Fluid or approved
automatic transmission fluids such as Dexron III, Dexron VI, Mercon V, Mercon LV, or any synthetic
Multi-Vehicle automatic transmission fluid.
⚠ WARNING Do not run the Power Unit without Hydraulic Fluid; damage may occur.
To fill the Hydraulic Fluid Reservoir:
1. Remove the Reservoir Cap and set it aside.
Take care to
keep contaminants out
of the Hydraulic Fluid Reservoir.
2. Fill the Hydraulic Fluid Reservoir on the Power Unit with the appropriate amount of Hydraulic Fluid.
3. When the Reservoir is full (approximately 1-in. from top), replace the Reservoir Cap.
Do not connect the Power Unit to a power source at this point
.