Fig. 55
12. Remove index mechanism
Index Mechanism Installation
1. Reverse removal procedure to install.
2. Torque mounting screws holding upper housing
to slicer base 60 in.-lbs.
NOTE: Two long screws go in bottom two holes.
3. Check gauge plate for proper adjustment as
outlined under GAUGE PLATE ADJUSTMENT .
4. Check slicer for proper operation.
X13 SLICER - REMOVAL AND REPLACEMENT OF PARTS
F25332 Rev. A (0718) Page 22 of 36