www.anglemaster.com
Finding 0° on Top Face – Scratch lightly with grinding stone Set 0°
On a BRAND NEW BLADE: Scratch across the face, instead of zero °, press reset button to set left hand “Where
you are” display to zero; hold reset button and press + or – buttons to increment the “where-you-are” display
to the correct angle for that blade: -7° Small; -9° Medium; -12° Large; the angle for that blade as ground by the
manufacturer – there is no wear yet. Add a maximum of 1° to this setting before truing the face of the blade.
Scratch: too back
Scratch: too forward
Too Back
Too Forward Correct
Press
the
RESET
button to set the left
“Where-you-are”
display to the current
angle of Zero.
ANGLEMASTER 3000
Rotate to
Top Face
Mount Bedknife against Tabs
Turn on Magnet and
secure bedknife to
Brackets.
Release and rotate
tabs away.