BestCode Next Series 8 Technical Manual October 2022 Page 177 of 290
Ink fluid level could not be determined.
Ink float switch is not plugged in. Check connection on J32.
Ink float switch is not operating correctly. Replace the Ink Float Switch.
Ink fluid level too high to operate.
Ink float switch is not operating correctly. Inspect the fluid level in the ink tank. If fluid level is OK,
replace the Ink float switch.
Ink tank is over-filled. Drain the ink from the tank and install fresh ink. Ensure that the CPU Hardware
Generation is set correct to the fluidic system and check for faulty valves.
SmartFill ink label required.
Scan SmartFill ink label. Do not add Ink Bottle. Occurs when fluid is added but SmartFill label is not
read. Review how to add Ink here.
SmartFill ink label required.
Check Ink Level and inspect Ink Level switch function.
"SmartFill ink label required."
Check Ink Level and inspect Ink Level switch function.
"SmartFill ink label required."
Check Ink Level and inspect Ink Level switch function.
Scan SmartFill Label only. Train operators on properly adding fluids.
"SmartFill ink label required."
Same as 10-800A, except only occurs at Jet Start.