BestCode Next Series 8 Technical Manual October 2022 Page 40 of 290
Counters
Video Guide for Counters: https://youtu.be/tQP9Z1Vem5g?t=437
Counter
Selects the unique counter to be customized
Counter 1-4
Incrementation
The counter will increment by this value for each count.
May be negative.
-20 to 20
Start Count
The number to begin counting from
0-999999999
End Count
The number to stop counting at.
0-999999999
Leading Zeroes
On
00000001
Off
1
Repeat
How many times to repeat the printed number before
incrementing it
0-10000
Count Trigger
Print
The counter increases when there is a Print
Photocell
The counter increases when there is a Print Trigger
Counter Resets
Off
The counter will never reset. It will print until the counter reaches the maximum and then it
will reset to 0 and count again
Select
The counter will reset when the message is selected, edited, or when the user define value
is changed.
Print Off
The Printer High Voltage will disable when the counter reachers the End Count value. Then
will prevent the printer from coding any more product until the counter is reset.