CYCLOPS-I BT Scanner Configuration Guide 19
6.3. Data Format of Data File
The recode size is 128-Byte/record in <data.txt>. Scanned data will be saved into this data file
according to details as described in <9.2.4 Batch Mode Settings>. Data format of <data.txt>
is described as in the following.
[Mark][Checksum][Delimiter][Timestamp][Delimiter][Data][Termination]
Field
Bytes
Default Value
Description
Mark
1
Special Mark
: Added
: Deleted
: Send-Out OK
Check-sum
4
Check-sum:
2-digital of ASCII Code
Delimiter
1
“Separator mark
Time Stamp
19
YYYY/MM/DD,hh:mm:ss
Date & Time:
Separator of Date & Time is
the same as Delimiter field.
Delimiter
1
“Separator mark
Scanned
Data
100
Scanned data:
For scanned data length shorter
than 100-Byte, system of
CYCLOPS-I will fill blanks
behind the scanned data to fill all
100-Byte.
Record
Termination
2
CRLF(0x0D0A)
Terminator of each record.