62
Impedance
Z
and Phase Angle
θ
Range
Display Range
Accuracy
Recommended
Equivalent Mode
Ze
e
100Hz
-- 10kHz
10M
4.000M10.000M
3%+5 digits
1.75
Parallel
4M
400.0k3.9999M
1%+3 digits
0.75
Parallel
400k
40.00k399.99k
0.35%+2 digits
0.25
Parallel
40k
4.000k39.999k
0.1%+2 digits
0.1
Parallel
4k
400.03.9999k
0.1%+2 digits
0.1
----
400
40.00399.99
0.1%+2 digits
0.1
Series
40
4.00039.999
0.35%+2 digits
0.25
Series
4
0.40003.9999
1.00%+3 digits
0.60
Series
0.4
0.00000.3999
3.00%+5 digits
Not Specified
Series
100kHz
10M
4.000M10.000M
8%+ 20 digits
4.6
Parallel
4M
400.0k3.9999M
3%+10 digits
1.75
Parallel
400k
40.00k399.99k
1.2%+5 digits
0.69
Parallel
40k
4.000k39.999k
0.8%+2 digits
0.46
Parallel
4k
400.03.9999k
0.5%+2 digits
0.3
----
400
40.00399.99
0.5%+2 digits
0.3
Series
40
4.00039.999
0.8%+5 digits
0.46
Series
4
0.40003.9999
2.5%+10 digits
1.43
Series
0.4
0.00000.3999
6%+20 digits
Not Specified
Series
*Note: Accuracy of De is assessed when De <0.5
DCR
Range
Display Range
Accuracy
DCR
20M
4.000M20.000M
2 %+20 digits
4M
400.0k3.9999M
1%+10 digits
400k
40.00k399.99k
0.5%+5 digits
40k
4.000k39.999k
0.1%+2 digits
4k
400.03.9999k
0.1%+2 digits
400
40.00399.99
0.1%+2 digits
40
4.00039.999
0.1%+2 digits
4
0.40003.9999
0.5%+10 digits
0.4
0.00000.3999
2%+20 digits

Table of Contents