Menu Main
Feature
Parameter Parameter
Feature
Detailed
Description
PB
PC
PD
PE
PF
Electric lock
auxiliary
function
Infrared
terminal set
Soft start time
Remote
control mode
System set
0
1
0
1
1
2
3
0
1
00
...
05
...
09
Open
(factory set)
Close
Reverse rst
NO mode
(factory set)
NC mode
1s (factory set)
2s
3s
One Gate Mode
Two Gates Mode
Nothing
...
Factory reset
...
Nothing
Factory setting Motor 2 will activate after 1
second to allow gate lock to release.
Setting PB to 1 will make Motor 2 reverse
(Close) for 0.5 seconds to help release
pressure off the lock before allowing Motor
2 to activate.
If you run safety beams, you will need to
set PC to 1. Factory setting allows you to
operate without safety beams.
You can adjust the soft start time of your
gate. Recommended to leave this setting
on 1
If you have 2 gate opener kits on the one
property and are within 100 metres of each
other, you will need set your control board
to FE setting to 1. This will have your
remote set to:
Gate 1
Button A – Full open/close
Button B – Party mode
Gate 2
Button C – Full open/close
Button D – Party mode
Factory set mode 0
This setting will put your control board back
to factory settings and put your unit to Dual
swing gates. This would then need to be
adjusted to suit a single swing gate.