39
5. Continue steps 3 & 4 to program the desired IP address value.
6. At the end the display will show EXIT AND SAVE. Press the MENU button.
7. The display will show JUST EXIT. Press the MENU button. SUBNET MASK? will be shown on the display.
Changing Subnet Mask address
1. Each time you press the CHOICE button a different address will be displayed (see list below).
0.0.0.0 (reserved) 255.255.128.0 (class C)
128.0.0.0 (class A) 255.255.192.0
192.0.0.0 255.255.224.0
224.0.0.0 255.255.240.0
240.0.0.0 255.255.248.0
248.0.0.0 255.255.252.0
252.0.0.0 255.255.254.0
254.0.0.0 255.255.255.0
255.0.0.0 255.255.255.128
255.128.0.0 (class B) 255.255.255.192
255.192.0.0 255.255.255.224
255.224.0.0 255.255.255.240
255.240.0.0 255.255.255.248
255.248.0.0 255.255.255.252
255.252.0.0 255.255.255.254 (unusable)
255.254.0.0 255.255.255.255 (host-single address)
255.255.0.0 “
2. Once you have the address you want, press the TEST button. The display will show EXIT AND SAVE. Press the
MENU button.
3. The display will show JUST EXIT. Press the MENU button. DEFAULT GATEWAY? will be shown on the display.
Changing Default Gateway address
1. The blinking cursor indicates the current Default Gateway numeric value. Every time you press the CHOICE
button the numeric value will change.
2. Using the TEST button will move you over to the next numeric value.
3. Continue steps 1 & 2 to program the desired Default Gateway address value.
4. At the end the display will show EXIT AND SAVE. Press the TEST button.
5. The printer will reset and the static IP address settings will be saved.