Fault description Cause Remedy Personnel
Check the pipes for damage
and rectify
, if necessary
Rule out any leaks on compo-
nents (pressure gauges, ball
valves etc.)
Suction line completely
empty
Lower the pump* and prevent
emptying of the pump chamber
,
e.g. with 90° pipe bend at the
inlet
Otherwise provide start-up
volume
Mechanics
Suction height too large
(> 8 m / 26.25 ft)*
Reduce the suction height
(lower the pump)*
Mechanics
Diameter of the suction
line (side of inlet) too
large*
Adjust the pipe diameter to the
pump output of the rotary lobe
pump*
Mechanics
Several or all suction
lines open with cross-
linked pipes
Only open the shut-off device of
the suction line which is cur-
rently in pump operation
Mechanics
Viscosity of pumped
medium too high*
Reduce the viscosity when pos-
sible*
Change the pump position* or
install an auger upstream
Mechanics
Build-up of air pockets
(pump could not dis-
charge air on pressure
side)
Provide venting Mechanics
Rotors damaged due to
dry run
Replace the rotors
Replace mechanical seal
(strongly recommended if rotors
were damaged due to dry run)
Determine the cause of dry run
and eliminate it
Mechanics
Rotors damaged due to
foreign bodies
Replace the rotors
Install a macerator (Multi-
crusher, Multichopper) and a
stone trap upstream, if neces-
sary
Mechanics
Operation
BA-Classic FL_en-US, 03.05.2018www.boerger.de / www.boerger.com98