Fault description Cause Remedy Personnel
Incorrect parameteriza-
tion of the control unit or
frequency converter
Correct the setting
Check that the frequency con-
verter is suitable (it must emit a
constant torque)
Qualified
electricians
Pressure line (side of
outlet) is closed or
blocked
Open shut-off device
Clean the pressure line
Mechanics
Long-fibrous or film-like
particles have become
wrapped around the
rotors
Remove all foreign bodies
Install a macerator (Multi-
crusher, Multichopper) and a
stone trap upstream, if neces-
sary
Mechanics
Sediment of the
pumped medium has
been deposited in the
pump chamber fol-
lowing a lengthy down-
time of the rotary lobe
pump
Clean the pump chamber
Close the valve of the inlet line
and clean the pump chamber
before longer downtimes
Mechanics
Polymer rotors have
expanded and press too
strongly against the
casing wall
Determine the chemical compo-
sition and temperature of the
pumped medium and use rotors
made from suitable materials
(test plates for testing the
expansion are available from
Börger GmbH)
Mechanics
Drive output too low Install a more powerful drive Mechanics
The pump does not
generate suction
Incorrect drive direction
of rotation, therefore
incorrect flow direction
Change the direction of drive
rotation
Mechanics
Suction line (side of
inlet) closed or blocked
Open shut-off device
Clean the suction line
Mechanics
Suction connection is
leaky
Tighten the screws on the
flange connection cross-wise
with uniform strength
Check the seal and replace, if
necessary
Mechanics
Operation
BA-Classic FL_en-US, 03.05.2018 www.boerger.de / www.boerger.com 97