Bosch Sensortec"| BST-BMP581-DS004-02 10 | 74
Modifications reserved | Data subject to change
without notice Document number: BST-BMP581-DS004-02
Table 2: Temperature Performance
Parameter
Symbol
Comment
Min
Typ
Max
Unit
Temperature
measurement
range
Temperature
measured in
the entire
temperature
operational
range
-40
85
°C
Absolute accuracy
temperature
A
t_abs
-5 .. 55°C
- 1
+/- 0.5
+ 1
K
Absolute accuracy
temperature full
range
A
t_abs_full
-40 .. 85°C
- 1.5
+/- 0.5
+ 1.5
K
Relative accuracy
temperature
A
t_rel_full
-40 .. 85°C,
20 K steps
- 0.5
+ 0.5
K
Temperature data
resolution
A
t_res
1/65536
+ 1.0
°C
Table 3: Mechanical characteristics
Parameter
Symbol
Comment
Min
Typ
Max
Unit
Package footprint
dimensions
1.95 x 1.95
2.0 x 2.0
2.05 x 2.05
mm
2
Package height
0.7
0.75
0.8
mm
Number of pins
10
Package category
Moisture
sensitivity
level
MSL1
Table 4: Electrical characteristics
Parameter Symbol Comment Min Typ Max Unit
Power supply
voltage
VDD
1.71
1.8 / 3.3
3.6
V
Power supply
voltage I/Os
VDDIO
1.08
1.2/ 1.8 / 3.3
3.6
V
Supply ramp time
t_VDDramp &
t_VDDIOramp
10% to 90% of
target voltage
0.01
a
10
ms
Operational
temperature
range
TOP_full
-40
85
°C
ODR Accuracy
-40..85°C
-10
+10
%
Power-up time
t_powup
Time to first
communication
after both VDD >
VDDmin and
2
ms