EasyManua.ls Logo

Bosch BMP581 - Table 1: Pressure Performance

Bosch BMP581
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Bosch Sensortec"| BST-BMP581-DS004-02 8 | 74
Modifications reserved | Data subject to change
without notice Document number: BST-BMP581-DS004-02
2 Specification
If not stated otherwise,
All values are valid over the full voltage range
Minimum/maximum values are ±3 sigma values
Typical values of currents and state machine timings are determined at 25 °C
Minimum/maximum values of currents are valid for the temperature range from -40°C…+85°C
Minimum/maximum values of timings are valid for the temperature range from -40°C…+85°C
Environmental conditions like temperature, RF, humidity are constant, unless ranges for these are specified
Pressure performance is given in Table 1, temperature performance in Table 2. If not stated otherwise:
Parameters are valid for the range 300 1100 hPa @ -5 65 °C
Parameters are valid before soldering after storage in standard conditions according to Table 6.
Performance parameters are derived without MSL1 preconditioning.
Post-solder refers to 3x reflow soldering after storage in standard conditions.
Table 1 : Pressure Performance
Parameter
Symbol
Min
Typ
Max
Unit
Pressure
measurement
range
P
30
125
kPa
Temperature
range
T
A
measured in
the entire
temperature
operational
range
-40
85
°C
Relative pressure
accuracy
A
p_rel
hPa, 15
55 °C, 10
± 6
Pa
Absolute Pressure
accuracy
A
p_abs
hPa, -5
65 °C,
including
TCO
± 30
Pa
Offset temperature
coefficient
TCO
hPa, -5
65 °C, 10 K
± 0.5
Pa/K
Pressure data
resolution
A
p_res
1/64
Pa
Pressure noise
V
p_low_power
lowest
power
0.78
0.95
PaRMS
Pressure noise
V
p_hi_res
high
resolution
0.21
0.25
PaRMS

Related product manuals