Bosch BMP581 - Table 10: IIR Filter Settings and Bandwidth

Bosch BMP581
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Bosch Sensortec"| BST-BMP581-DS004-02 21 | 74
Modifications reserved | Data subject to change
without notice Document number: BST-BMP581-DS004-02
Figure 3: Step response at different IIR filter settings
Figure 4: Step response at different IIR filter settings on log scale and different threshold limits in dashed lines (3dB, 90%, 95%,
99.5%, 100%)
Table 10: IIR filter settings and bandwidth
Register value
Filter
coefficient
Normalized bandwidth (
-3db cutoff frequency)
0x0
0
Bypass
0x1
1
0.1147
0x2
3
0.0459
0x3
7
0.0212
0x4
15
0.01025
0x5
31
0.005041
0x6
63
0.00250
0x7
127
0.00125
The IIR filter can be independently programmed for temperature and pressure with the fields DSP_IIR.set_iir_t and
DSP_IIR.set_iir_p. The value “0x0is used to bypass the filter. The IIR filter is reset when a transition from sleep mode
to NORMAL or CONTINUOUS mode occurs. That means that the first measurment value will be the initial content of
the filter. A manual reset of the filter, e.g. when using forced mode, can be triggered by asserting the register field
DSP_- CONFIG.iir_flush_forced_en.