Bosch Sensortec"| BST-BMP581-DS004-02 64 | 74
Modifications reserved | Data subject to change
without notice Document number: BST-BMP581-DS004-02
Standby mode: no measurement ongoing
Normal mode: measurement in configured ODR grid
Forced mode: forced one-time measurement
Non-Stop mode: repetitive measurements without further
duty-cycling
odr:(bit offset: 2) ODR Selection
Note: the configured ODR might be invalid in combination with OSR configuration This is observable with the flag
odr_is_valid. If configured ODR/OSR settings are invalid, default OSR settings will be used. The effective OSR
settings for P/T can be read from osr_t_eff and osr_p_eff
240.000 Hz (Error = 0.00)
218.537 Hz (Error = 0.67)
199.111 Hz (Error = 0.44)
179.200 Hz (Error = 0.44)
160.000 Hz (Error = 0.00)
149.333 Hz (Error = 0.44)
140.000 Hz (Error = 0.00)
129.855 Hz (Error = 0.11)
120.000 Hz (Error = 0.00)
110.164 Hz (Error = 0.15)
100.299 Hz (Error = 0.30)
deep_dis:(bit offset: 7) If asserted, disables the deep standby (Note: This field cannot be changed during an ongoing
P/T conversion.)