SystemModules
FlexibleAutomation
4−25
Humidity Class F to DIN 40040
Dimensions Dual Eurocard format
Inputs 512 with process image (I) I0.0−I63.7
or
512 directly with process image tracking (II) II0.0−II63.7
512 additional inputs (EI) EI0.0−EI63.7
Outputs 512 with process image (O) O0.0−O63.7
or
512 directly with process image tracking (IO) IO0.0−IO63.7
512 additional outputs (EO) EO0.0−EO63.7
Marker 2048, M0.0−M255.7
Standard definition M0.0−M127.7 non−remanent
M128.0−M255.7 remanent
Selectable Remanency Range in OM7:M0.0−M255.7
Special Markers 32, SM0.0−SM31.7
Times Range 0.01−9990s
Increments 0.01s, 0.1s, 1.0s, 10.0s
128 internal, T0−T127
Standard definition T0−T63 non−remanent
T64−T127 remanent