SystemModules
FlexibleAutomation
4−13
4.1.6 Specifications
NT300 NT301
InputVoltage
Frequency
47−63Hz 47−63Hz
LineVoltage >187Vor>93V,resp.
LineFuse
M1.6A230V M6.3A230V
InternalSupplyVoltage
forlogiccircuits
forperipheralbus
(isolatedforinterfaces)
InternalCurrentSupply
isolated
isolated
4A
1.8A
0.5A
−0.1A
isolated
isolated
8A
3A
1A
−0.5A
OvervoltageDetection
at+6.0V
at+13.5V
noneisolated
UndervoltageDetection
BufferBattery
BatteryVoltage
BatteryLife
BufferTime
+3.4Varederivedfrom5Vinternalvoltage
1.75Ah 5.2Ah
1year
ProtectionofGeneratedVoltages
Allvoltagesareelectronically
protectedagainstovervoltages
andshort−circuits
FloatingContact
Max.SwitchingVoltage
CurrentCapacity
24VDC
2A
Width 2modulewidth
HumidityClass FtoDIN40040
MechanicalStress
Installationinstationaryequipment
notfreefromvibration
TemperatureMonitoring +70C+10%−0%
TemperatureRange
Operating
Non−operating
55Cwithoutflowofair
−20to+70C
_
_
_
220V−15% 230V+10%
110V−15%
115V+10%
+5V
+12V
+_
12V
+5V
+12V
+12V
−12V
+5V
+12V
+12V
−12V
+5V
+12V
+12V
at+4.6V
at+10.0V
noneisolated
+5V
+12V
+12V