D9412GV2/D7412GV2 | Troubleshooting Guide | 3.0 Troubleshooting
.
Bosch Security Systems, Inc. | 11/05 | F01U011024B 39
3.2.4 DS7432 Eight-Input Remote Module
Table 19: Multiplex Devices
DS7432s occupy groups of eight points; however,
when programming the DS7432 with the Multiplex
Point Programmer, they must be programmed as four
sets of dual points. For example, if using a DS7432 on
the system for Points 9 through 16, program Points 9,
11, 13, and 15 as dual points.
Product Point Type
DS7432 Eight-Input Remote Module 6
DS7450 Flush-Mount Single Multiplex
Contact Point
1
DS7452 Surface-Mount Single Multiplex 1
3.2.5 DS7465 Input/Output Module
Contact Point
The relay output number assigned to this module is
directly associated with the point number assigned to
it. For example, if this device was programmed as
Point 27, the relay number is also 27.
DS7457 Single Multiplex Input Module 2
DS7460 Dual Zone Input Module 6
DS7465 Input/Output Module 3
MX775 (DS7470) Multiplex Passive 2
3.2.6 Removing a Point from the D8125MUX
Infrared (PIR) Intrusion Detector – 50 ft.
1. Apply power to the D5060 and connect the
programmer to the D8125MUX only.
(15 m) Mirror
MX934 (DS7471) Multiplex PIR Intrusion
Detector – 35 ft. (11 m) Mirror
2
2. Enter the address of the point you want to
remove.
MX938 (DS7472) Ceiling Mount Multiplex 2
PIR Intrusion Detector
3. When prompted for a point type, press [0]. Refer
to
MX540 (DS7473) Multiplex PIR Intrusion
Detector – 40 ft. (12 m) Fresnel Lens
2
. Table 20
Figure 21: D8125MUX Multiplex Bus Interface
Module
MX794 (DS7474) Multiplex Long Range 2
PIR Intrusion Detector
MX950 (DS7476) Multiplex PIR/Microwave
TriTech Intrusion Detector
2
RESET
12V IN OUT GND
ZONEX BUS
FIRE MANUAL
WALK TEST
PROG
PORT
+- +- + - +-
POWER A
MUX BUS A
POWER B
MUX BUS B
Operation LED
MX835 (DS7477) Multiplex PIR/Microwave 2
TriTech Intrusion Detector with Pet
Immunity
Table 20: Point Type Entry Code
Decimal Value Point Type
0 Remove point from D8125MUX
1 Contact
2 Sensor (or Single Point Module)
3 I/O Module
4 MUX smoke without low temperature
Figure 22: Connecting the Transient Noise
Suppression Diode (P/N: NS001-20)
5 MUX smoke with low temperature
6 Dual point
Cathode
end
+ Mu x B us
- Mux Bus