D9412GV2/D7412GV2 | Troubleshooting Guide | 3.0 Troubleshooting
.
Bosch Security Systems, Inc. | 11/05 | F01U011024B 87
Figure 46: Open the IP Address and Port
14. Press [Enter] to accept the default Connect Mode
of (CC). If CC is not the default, type [cc]
[ENTER] to change it.
15. Type [00] if the unique port number typed in
above is the same that was used for the D6680.
Type [07] if the unique port number typed above
is different from the port number used for the
D6680. Press [ENTER].
The connection fails the first time. This is
normal.
If you select 00 for the Datagram type, the
remote IP and port number do not apply.
6. Press [F3] to show the last line typed.
Skip to Step 18 to enable encryption.
7. Backspace over the 1 and type: 9999
Example: open 172.17.10.70 9999
To use Datagram Type 07, firmware
version 1.5d or greater is required in the
Figure 47: Change Port from 1 to 9999
Xport module. Refer to the DeviceInstaller
Operation and Installation Guide
(P/N: 4998138688) for more information.
For more information on Datagram Types,
refer to the D6600 NetCom System
Guide (P/N: 4998122712).
8. Press [ENTER] to show the setup menu.
16. If using dynamic host configuration protocol
(DHCP), press [ENTER] four times to specify
0.0.0.0 for remote IP address. It might be
necessary to type the actual IP address.
9. Press [1] [ENTER] to enter setup Channel 1
configuration.
10. Press [ENTER] to accept the Baud Rate default of
(9600). If 9600 is not the default, type 9600 and
press [ENTER] to change it.
17. Enter the same port number that was used for the
D6680 and press [ENTER].
11. Press [ENTER] to accept the default I/F Mode of
(4C). If 4C is not the default, type [4c] [ENTER] to
change it
18. If you want to enable encryption, select 6-
Security from the main menu and continue to the
next step.
If encryption is enabled on the network
12. Press [ENTER] to accept the default Flow of (00).
If 00 is not the default, type [00] [ENTER] to
change it.
interface module (NIM), it must be enabled
at the D6680 with the same key.
The software revision of the Network
Interface Module connected to the NIM
must be 1.2 or greater. To check the
13. Type a unique port number for the particular local-
area network (LAN) to which the device is
connected, and then press [ENTER].
version, execute a telnet command to the
unit. Allow the version number to show for
five seconds before you press [Enter].
Datagram Type 07 must be used if the
unique port number is not the same one
used for the D6680.
The port number shown here is an
example and might not be the same.