64 en | Error Codes MIC IP ultra 7100i MIC IP starlight 7100i
2019-12 | 1.2 | Installation Manual Bosch Security Systems
If this action does not resolve the problem,
contact the nearest Bosch Security Systems
Service Center. The Service Center may
request information from the diagnostics log
of the camera (accessible from the Service
menu).
23 An internal error has occurred.
(The optical video screen becomes
blue for 1 or 2 seconds during the
camera’s recovery procedure.)
If this problem begins to occur on a regular
basis:
1. Verify that the power source to the camera
is not experiencing brown-out conditions.
2. Verify that the camera’s earth ground
connection is attached per earlier
instructions.
If these actions do not resolve this problem,
contact the nearest Bosch Security Systems
Service Center.
!
Caution!
If you choose not to use a switch or midspan with the appropriate Power Sourcing Equipment
(PSE) chip, then the MIC camera will not recognize the PoE as compliant, and the camera
firmware may disable some or all functionality.