46 en | Technical Data PLENA matrix
2020-12 | V1.1 |
User manual
Bosch Security Systems B.V.
Logic inputs
Connector 2‑pole Phoenix terminal (metric)
8CS and WCP (RS485)
Call station connector 1x RJ45
Wall control panel connector 1x RJ45
Amplifier 2x
Connector RJ45
Nominal level 1V
Impedance <100ohm
Ethernet (10/100Mbit/s) 1x
Connector RJ45
Notice!
Maximum load means maximum two multi-channel amplifiers, call stations and wall control
panels connected.
11.1.2 Multi Channel DSP Amplifier
Power supply
Mains voltage:
– Nominal input voltage 100-240VAC ±10%, 50/60Hz
– Input voltage limits 90-264VAC
Power consumption (-6dB/idle/standby):
– PLM‑4P125 254W / 27W / 6W
– PLM‑4P220 412W / 36W / 6W
Performance
Rated outputs voltage/impedance 100V / 70V / 8ohm / 4ohm
Rated output power per channel (continous *):
– PLM‑4P125 130W
– PLM‑4P220 220W