4.1.5. REMOVAL FROM THE CYLINDER
1. Unscrew the four M6 bolts (bolt A, Figure 4)
2. Remove the CIMS Mk IV for the adapter ring (some force may be required because of the
o-ring).
4.2. ELECTRICAL INSTALLATION
4.2.1. WIRING
A shielded twisted pair cable with 3x2 or 4x2 twisted pairs (minimum 0.25mm
2
) is required. With a
3x2 cable, the diagnostic functionality cannot be used and is therefore not recommended.
Losses in a transmission line are a complex combination of DC conductor loss, AC loss due to skin
effect, leakage and losses in the dielectric. It is therefore very important to select the appropriate
cable, like the one selected and delivered specially for CIMS:
Super-Paar-Tronic 340-C-Pur 4x2x0.25.
The cable consists of four twisted pairs (4x2x0.25). The cable has an overall shielding from tinned
copper braiding and a full polyurethane outer jacket. The cable is suitable for both inside and
outside use, as it is resistant to weather, ozone and UV-radiation, furthermore it has a very good oil
resistance.
Orientation pin
Bolt G (4x)
Figure 13: Adapter ring with bolts and sealing-rings.
Sealing ring
Figure 14: Adapter ring bottom.